DIN 4102

Fire & smoke protection doors

T30, T60, T90 — the classification says how many minutes the door withstands fire. It protects escape routes, separates fire compartments and is subject to mandatory inspection.

At a glance.

Fire doors divide a building into compartments that a fire cannot leave for a defined period. That period is in the designation: T30 withstands 30 minutes, T90 ninety.

Smoke protection doors pursue a different aim: they hold smoke back so that escape and rescue routes stay passable. Both requirements can be combined.

We supply, fit and inspect both types — and document the inspections so that they stand up to an inspection visit.

  • T30 / T60 / T90 classification by fire resistance period
  • Protection of escape routes and separation of fire compartments
  • Smoke-tight versions for additional protection of people
  • Mandatory inspections including records
  • What you get: minimised liability risk and assured operational safety

Kenndaten

Leitnorm
DIN 4102
Fire resistance
T30 – T90
Regelwerke
5
Prüfpunkte
3

Standards & regulations.

The rules this work is planned, installed, signed off and maintained against.

DIN 4102-5
Standard 01 / 05

Fire-resistant closures — Terminology and requirements

Basis for the T30, T60 and T90 classification.

DIN 4102-18
Standard 02 / 05

Fire-resistant closures — Verification

Requirements for the proof of usability.

DIN EN 1634-1
Standard 03 / 05

Fire resistance tests for door assemblies

European test method for determining the fire resistance duration.

DIN EN 16034
Standard 04 / 05

Fire and smoke control door and shutter sets — Product standard

Performance characteristics for CE marking.

DIN 18095
Standard 05 / 05

Smoke control doors

Requirements for smoke-tight closures.

From survey to maintenance.

  1. 01

    Site survey

    Record the doors, check markings and evidence of fitness for use, document defects.

  2. 02

    Concept & planning

    Define the required classification for each opening; determine hardware, closing sequence and seals.

  3. 03

    Installation

    Professional fitting with approved fixings — the installation decides the effectiveness.

  4. 04

    Acceptance & commissioning

    Function and closing test, marking, entry in the logbook.

  5. 05

    Maintenance & documentation

    Recurring inspection of closing sequence, seals and hardware, with a record.

Inspect, maintain, document.

What has to be inspected how often — and the standard each interval rests on.

annually
Inspection 01 / 03

Functional and closing test

  • Manufacturer's specification / operator's duty
monthly
Inspection 02 / 03

Visual check that the door closes unobstructed

  • Operator's duty
annually
Inspection 03 / 03

Inspection of self-closing devices

  • Building code law

What you get.

Benefit 01 / 03

Clear classification

Every opening gets the door the fire protection concept requires there — no more, no less.

Benefit 02 / 03

Demonstrable inspection

Recorded inspections rather than verbal assurance.

Benefit 03 / 03

Less liability risk

Documented operational safety relieves the owner and the managing agent.

Questions.

Fire doors

Sprechen wir über Ihr Objekt.

Schildern Sie uns kurz die Situation — wir sagen Ihnen, was tatsächlich erforderlich ist und was es kostet.

(030) 240 32 950