DIN 14677

Hold-open systems (TFA / FSA)

Open in everyday use, closed automatically in a fire. Hold-open systems resolve the conflict between step-free passage and closed fire compartments.

At a glance.

Fire doors only work when they are closed. In everyday use they get in the way wherever people and material have to pass through constantly — and are then wedged open, which defeats the fire protection.

A hold-open system holds the door open electromagnetically and releases it as soon as a detector triggers or the power supply fails. The passage stays step-free and the fire compartment stays effective.

  • Smoke or heat detectors on both sides of the opening
  • Hold-open control unit with power supply
  • Electromagnetic holders that keep the door leaf open
  • Manual release button for releasing the door by hand
  • Open in everyday use – closed automatically in a fire
  • Step-free passage with no compromise on fire protection
  • Components: smoke/heat detectors, control unit, electromagnetic holders, release button
  • Annual maintenance by competent persons to DIN 14677

Kenndaten

Leitnorm
DIN 14677
Inspection interval
Jährlich
Regelwerke
3
Prüfpunkte
2

Standards & regulations.

The rules this work is planned, installed, signed off and maintained against.

DIN 14677
Standard 01 / 03

Maintenance of hold-open systems

Requires recurring maintenance by a competent person and its documentation.

DIBt-Zulassung
Standard 02 / 03

General building authority approval

Hold-open systems require approval. Only approved combinations of components may be installed.

DIN EN 14637
Standard 03 / 03

Electrically controlled hold-open systems

Product requirements for hold-open systems for fire and smoke doors.

From survey to maintenance.

  1. 01

    Site survey

    Record doors, approvals and existing hold-open arrangements; document impermissible wedges and hooks.

  2. 02

    Concept & planning

    Select a permissible component combination, define detector positions and release points.

  3. 03

    Installation

    Fit and commission the control unit, detectors, electromagnetic holders and release buttons.

  4. 04

    Acceptance & commissioning

    Release test on every door, briefing, entry in the logbook.

  5. 05

    Maintenance & documentation

    Annual maintenance to DIN 14677 with evidence from the competent person.

Inspect, maintain, document.

What has to be inspected how often — and the standard each interval rests on.

annually
Inspection 01 / 02

Maintenance by a competent person

  • DIN 14677
monthly
Inspection 02 / 02

Visual check of function and wedging

  • Operator's duty

What you get.

Benefit 01 / 03

An end to door wedges

The most common fire protection defect in existing buildings disappears, because the door is legally allowed to stand open.

Benefit 02 / 03

Step-free and compliant

Both at once — without anyone having to close the door by hand.

Benefit 03 / 03

Evidence for the inspection visit

Documented maintenance that stands up to scrutiny.