Portable fire extinguishers — Maintenance
Requires recurring maintenance by a qualified person and specifies what is inspected and documented. Usual interval: two years.
The fire extinguisher is the only fire protection device a layperson operates when it matters. Calculate the requirement in extinguishing agent units, equip correctly, sign the locations, inspect every two years — and keep the evidence.
Fire extinguishers look unremarkable and are legally demanding. How many a building needs does not follow from the number of rooms but from the floor area and the fire risk — calculated in extinguishing agent units to ASR A2.2. The wrong extinguishing agent, too few units, and a location that is blocked or unsigned are the three defects most commonly found during inspection visits.
FireLux determines the requirement, supplies the equipment, signs the locations, carries out the two-yearly maintenance through qualified persons, and keeps the evidence so that it stands up to scrutiny by an authority, an employers' liability insurance association or an insurer.
Kenndaten
The rules this work is planned, installed, signed off and maintained against.
Requires recurring maintenance by a qualified person and specifies what is inspected and documented. Usual interval: two years.
Construction, extinguishing capacity, labelling and fire classes of the device itself.
Determines, via extinguishing units, how many fire extinguishers a workplace needs, and regulates accessibility and fire wardens.
Specifies how fire extinguisher locations must be marked so they can be found in an emergency.
Source of the F001 fire safety sign for fire extinguishers.
CO₂ extinguishers are pressure equipment and are additionally subject to a recurring inspection of the pressure vessel.
Parts A, B and C — the wall notice, instruction of building occupants and duties for staff with special fire safety responsibilities.
Describes the training, number and duties of the fire wardens a company should appoint.
Record floor area, fire risk and fire classes; log the existing units and their inspection status.
Determine the extinguishing agent units, set the agent for each fire class, plan locations and signage.
Mount the units, sign the locations to ASR A1.3, update the fire safety regulations and notices.
Handover with a location plan, user briefing, clarification of who is appointed as fire safety assistant.
Maintenance every two years by qualified persons, with an inspection record for every individual unit.
What has to be inspected how often — and the standard each interval rests on.
The number of units follows from floor area and fire risk under ASR A2.2 — traceable for the building authority, the insurer and the employers' liability insurance association.
Extinguisher inspection runs on the same maintenance contract as the fire alarm system, hold-open systems and doors. One visit, one report.
We track the deadlines for every individual unit and get in touch before an inspection lapses.