DIN VDE 0833-3

Intruder & surveillance protection

FireLux plans and delivers complete solutions in intruder protection and surveillance technology — professional design, installation, inspection and maintenance to the applicable standards and directives.

At a glance.

The aim is reliable protection of people, assets and sensitive areas. That includes the professional design and installation, as well as the inspection and maintenance, of intruder alarm and surveillance systems.

Video surveillance is not a purely technical matter: every camera processes personal data. We plan fields of view, retention periods and warning signage to be compliant with data protection law from the outset.

  • Intruder alarm systems to DIN VDE 0833-3 and VdS directives
  • Video surveillance designed to comply with data protection law
  • Access control and perimeter protection
  • Connection to emergency and service monitoring centres
  • Inspection and maintenance to the applicable standards

Kenndaten

Leitnorm
DIN VDE 0833-3
Security grade
Grad 2 / 3
Regelwerke
5
Prüfpunkte
3

Standards & regulations.

The rules this work is planned, installed, signed off and maintained against.

DIN VDE 0833-3
Standard 01 / 05

Requirements for intrusion and hold-up alarm systems

Operation and maintenance of intrusion alarm systems.

DIN EN 50131
Standard 02 / 05

Alarm systems — Intrusion and hold-up systems

Defines security grades 1 to 4 and the associated requirements.

VdS 2311
Standard 03 / 05

Planning and installation of intrusion alarm systems

Guideline of the property insurers; often a precondition for insurance cover.

DIN EN 62676
Standard 04 / 05

Video surveillance systems

Requirements for system performance and image quality.

DSGVO
Standard 05 / 05

General Data Protection Regulation (GDPR)

Video surveillance processes personal data: the legal basis, retention period and notice obligation must be clarified without exception.

From survey to maintenance.

  1. 01

    Site survey

    Record the protection requirement, the building envelope, weak points and existing equipment.

  2. 02

    Concept & planning

    Set the security grade, plan detector and camera positions, settle data protection.

  3. 03

    Installation

    Fit and configure the control panel, detectors, cameras and monitoring centre connection.

  4. 04

    Acceptance & commissioning

    Function test, arming procedure, briefing of the users.

  5. 05

    Maintenance & documentation

    Recurring inspection and maintenance, documented for the insurer and the operator.

Inspect, maintain, document.

What has to be inspected how often — and the standard each interval rests on.

quarterly
Inspection 01 / 03

Inspection of the system

  • DIN VDE 0833-1
annually
Inspection 02 / 03

Maintenance of the system

  • DIN VDE 0833-1
annually
Inspection 03 / 03

Review of retention periods and camera fields of view

  • GDPR accountability obligation

What you get.

Benefit 01 / 03

One partner for fire and intrusion

Both trades from a single source, with shared cabling and one maintenance contract.

Benefit 02 / 03

Planned to insurer requirements

Designed to VdS where the insurer requires it.

Benefit 03 / 03

Data protection from the outset

Fields of view, retention periods and signage settled before the first camera goes up.

Questions.

Intruder protection

Sprechen wir über Ihr Objekt.

Schildern Sie uns kurz die Situation — wir sagen Ihnen, was tatsächlich erforderlich ist und was es kostet.

(030) 240 32 950